Dryer fuel
Dryer energy factors

UMN and NDSU: 0.02. Iowa State A2-31: 0.018 (range 0.010–0.025). Heat-reclaim and vacuum-cool dryers use less.

UMN and Iowa State: 0.01 for high-temperature drying.

Energy cost to dry

$0.216 per wet bushel

6.5 points removed · $0.0333 per bushel per point.

Propane2,600 gal · $4,160
Electricity1,300 kWh · $169
Total for 20,000 wet bu$4,329
Dry bushels after shrink (0.5% handling)18,362 bu
Cost per dry bushel$0.236

Break-even: the drying energy equals 5.2% of the crop's value at $4.20/bu. If waiting for field drydown would lose more than that to stalk lodging, ear drop or shatter, drying now is cheaper (NDSU method).

Energy only, unless you add other costs. Drying equipment ownership, labor and shrink are separate.

The rule of thumb

A high-temperature dryer burns about 0.02 gallons of propane per bushel per point of moisture removed and uses about 0.01 kWh of electricity per bushel per point (University of Minnesota; NDSU). Iowa State uses 0.018 gallons, with a range of 0.010 to 0.025 depending on the dryer.

propane (gal) = 0.02 × wet bushels × points removed cost per bu per point ≈ 0.02 × propane price

The University of Minnesota's example: drying from 21% to 16% (5 points) with $2.00 propane and $0.10 electricity costs 5 × (0.02 × $2.00 + 0.01 × $0.10) = $0.205 per bushel. NDSU's: 120 bushels from 25% to 15% takes 0.02 × 120 × 10 = 24 gallons.

Where the 0.02 comes from: about 0.72 lb of water per point per bushel, about 2,500 Btu to evaporate a pound of water in a high-temperature dryer, and 91,500 Btu in a gallon of propane (NDSU). Dryers with heat reclaim or vacuum cooling, and dryeration, can cut that by 20% or more.

Dry now or let it stand?

NDSU suggests dividing the drying cost per bushel by the grain price. The result is the share of the crop you could lose in the field before waiting costs more than drying. Corn typically dries in the field 0.3 to 1.0 point per day in early fall and much less by November, while stalk lodging, ear drop and harvest delays add up (Iowa State A2-32). See field drying vs. the dryer.

Natural-air drying

Bins with fans and no burner use electricity only. Minnesota studies average about 1 kWh per bushel to dry corn from 21% to 16% with a mid-October harvest (0.75 for Oct. 1, 1.25 for Nov. 1). Iowa State uses 0.33 kWh per bushel per point. This calculator models high-temperature dryers; for natural air, enter 0 for fuel and about 0.2–0.33 kWh per bushel per point under the energy factors.