Bin capacity is geometry plus a few judgment calls about the top of the grain, the floor and how much the grain has packed. Here's how to get measurements you can trust.

What to measure

  1. Diameter: the inside diameter. If you can only measure outside, measure the circumference and divide by 3.1416; the corrugation thickness is negligible.
  2. Depth at the wall: from the floor the grain sits on (the drying floor, not the foundation, if there is one) to where the grain touches the wall. Count wall rings and multiply by ring height if you can't reach.
  3. The top: level, peaked (highest in the center) or coned down (a funnel left by unloading from the center). For a peak, measure from the wall line to the top, or use the filling angle.
  4. Hopper: for hopper-bottom bins, the depth of the cone below the sidewall.

Doing the math

Bushels = 0.628 × D² × depth for the cylinder, plus 0.209 × D² × height for a peak or hopper, or minus that for a coned-down top (University of Nebraska; Iowa State C6-82). These use 0.8 bushels per cubic foot; the legal bushel is 1.2445 cubic feet (0.8036 bu/ft³), a 0.4% difference.

Safety

Never enter a bin to measure while grain is being unloaded or if the grain is crusted or bridged. Measure from the roof hatch or with a laser, lock out unloading equipment, and follow your state's grain bin safety guidance.

From volume to bushels sold

Bin math gives volume bushels. Multiply by test weight and divide by the standard weight for standard bushels, and allow for packing if you need an inventory figure. Bin capacity calculator · test weight calculator